Avago megaraid sas 9361 8i инструкция

MegaRAID® SAS 9361-8i

High Performance 12Gb/s PCI Express SATA+SAS RAID Controller

Unmatched RAID Performance for Next-Generation Servers and Storage

Key Features



High performance 12Gb/s data
transfer rates



Eight internal 12Gb/s SATA+SAS ports



Two mini-SAS SFF8643 internal
connectors (horizontal mount)



LSI SAS 3108: 1.2GHz PowerPC® 476
dual-core 12Gb/s ROC



PCI Express 3.0 host interface



1GB DDRIII cache memory



RAID levels 0, 1, 5, 6, 10, 50, and 60



Support for CacheVault® ash cache
protection

Key Advantages



12Gb/s solutions accelerate
performance for next-generation
datacenters, web and cloud



Delivers enterprise-class data
protection and security



Preserves investment in 6Gb/s and
3Gb/s drives



Support for Advanced Software
options



Connect up to 128 3Gb/s, 6Gb/s, or
12Gb/s SATA and SAS devices

The explosive growth of data in cloud and enterprise datacenters is driving the need for a

higher performance storage interface to speed the ability of critical applications to access data.

Avago rst-to-market 12Gb/s SAS solutions are designed to deliver the performance and data

protection capabilities required for the most demanding next-generation server and storage

platforms. Oering up to double the data transfer rate of 6Gb/s SAS solutions, 12Gb/s SAS allows

the SAS infrastructure to deliver bandwidth that can fully utilize that of PCI Express® 3.0 with a

single controller card. The MegaRAID SAS 9361-8i, with eight internal ports, delivers two 1.2GHz

PowerPC® processor cores and a 72-bit DDRIII interface that drives 1GB cache memory. Powered

by the LSI SAS 3108 dual-core ROC, the 9361-8i controller includes the latest PCI Express 3.0 and

12Gb/s SAS technology and helps users to support increased scaling of hard disk drives (HDDs) and

maximize the performance benets of solid state drives (SSDs).

Enterprise Data Protection

Standard support for the most popular RAID levels and accessories, including RAID 5, RAID 6, and

CacheVault® Flash cache protection module, further strengthen the data protection capabilities

of the MegaRAID SAS 9361-8i. A new enterprise feature employed by the 12Gb/s MegaRAID SAS

controllers is advanced drive diagnostic technology. In the event of a physical drive failure, the drive

is placed in shield state and the MegaRAID controller starts drive diagnostics to determine if the

drive is indeed failed or can be restored. This saves customers time, money and lost compute time

associated with transient drive failures and unnecessary drive returns.

Support for Advanced Software Options

The family of 12Gb/s MegaRAID controllers are designed to support Avago advanced software

options that provide system integrators and VARs with enhanced performance and data protection

capabilities. These software options help enable end users to address key business challenges while

helping to deliver a higher return on their IT investments. MegaRAID CacheCade™ Pro 2.0 software

(optional) and MegaRAID Fast Path software (included) boost transactional I/O performance of solid

state disk congurations, while SafeStore™ software enables enhanced data protection and security

when used with encryption capable devices.

Product Brief

Product Brief

MegaRAID SAS 9361-8i

Solution Provided Eight-port internal 12Gb dual core ROC-based SAS solution for data center, cloud, and performance-hungry

applications using up to 128 SAS or SATA devices

Physical Dimensions MD2 low prole (6.6” X 2.536”)

Connectors Two mini-SAS SFF8643 internal connectors (horizontal mount)

Device Support Up to 128 SAS and/or SATA devices

Host Bus Type x8 lane PCI Express 3.0 compliant

Data Transfer Rates Up to 12Gb/s per port

I/O Processor / SAS Controller LSI SAS 3108 dual core RAID on Chip (ROC)

Cache Memory 1GB 1866MHz DDRIII SDRAM

Cache Protection Optional CacheVault Flash Module (LSICVM02) – Includes CVFM04, CVPM02, mounting clip, and cable

Key RAID Data Protection
Features

Operating Temperature Maximum ambient: Controller Card: 55°C, with optional CacheVault accessory (LSICVM02): 55°C

Operating Voltage +3.3V, +12V

MTBF (Calculated) 1,343,187 hours

Hardware Warranty 3 years, free 5×8 phone support, advanced replacement option

Regulatory Certications EN55022, EN55024, EN60950, EN 61000-3-2, EN 61000-3-3; FCC Class A, Class B; UL1950; UL; CSA C22.2; VCCI; RRL for MIC;

MegaRAID Management Suite • MegaRAID Storage Manager

SSD Optimization • MegaRAID CacheCade Pro 2.0 Software leverages SSDs in front of HDD volumes to create high-capacity, high-performance

Compliances EMC: Class B-US (CFR 47, P15B); Canada (ICES-003); Japan (V-3/02.04); Europe (EN55022/EN55024); Australia/New Zealand

OS Support Extensive support includes Microsoft® Windows® Server 2012/8 & 7/2008/Vista/2003, Linux®, Solaris™ (x86), FreeBSD®, VMware®

• RAID levels 0, 1, 5, and 6

• RAID spans 10, 50, and 60

• Online Capacity Expansion (OCE)

• Online RAID Level Migration (RLM)

• Auto resume after loss of system power during array
rebuild or reconstruction (RLM)

• Single controller Multipathing

• Load Balancing

• Congurable stripe size up to 1MB

• Fast initialization for quick array setup

• Check Consistency for background data integrity

• SSD Support with SSD Guard™ technology

• Patrol read for media scanning and repairing

BSMI; C-tick

• StorCLI (command-line interface)

controller cache pools (Optional Upgrade)

• MegaRAID Fast Path Software provides high-performance I/O acceleration for SSD arrays connected to 6Gb/s MegaRAID

SATA+SAS controllers (Included)

(AS/NZS 3548); Safety: EN60950

and more.

Visit the download center for the most complete list of supported operating systems: www.lsi.com/support

• 64 logical drive support

• DDF compliant Conguration on Disk (COD)

• S.M.A.R.T support

• Global and dedicated Hot Spare with Revertible Hot Spare
support

– Automatic rebuild
– Enclosure anit y
– Emergency SATA hot spare for SAS arrays

• Enclosure management

– SES (inband)
– SGPIO (sideband)

• Databolt™ bandwidth optimizer technology support for
compatible expander-based enclosures

• Shielded state drive diagnostic technology

• CTRL-R (BIOS conguration utility)

• HII (UEFI Human Interface Infrastructure)

Ordering Information

MegaRAID SAS 9361-8i (Single Pack) LSICVM02 CacheVault Kit

MPN: 05-25420-08
OPN: LSI00417

MPN: 05-25444-00
OPN: LSI00418

Visit the Avago Server Storage website at: avagotech.com/server-storage

Avago, Avago Technologies, MegaRAID, and the Storage by LSI logo are trademarks of Avago Technologies. All other trademarks are the
property of their respective owners.

Copyright ©2015 Avago Technologies. All rights reserved. > 8.21.15

Инструкция по одному из вариантов установки RAID контроллера LSI MegaRAID SAS 9361-8i в сервер Gigabyte R182-N20-00. Естественно, RAID контроллер в комплекте с модулем CacheVault и батарейкой.

Имеем:

  • Сервер Gigabyte R182-N20-00
  • RAID контроллер LSI MegaRAID SAS 9361-8i
  • CacheVault Flash Module (LSICVM02) включает CVFM04, CVPM02, крепление и кабель
  • Кабель GIGABYTE 25CFM-800821-A4R: 2 шт
  • 8 дисков SAS

Сервер Gigabyte R182-N20-00 оборудован двумя полнопрофильными слотами расширения PCIe, в которые мы можем установить наш контроллер.

gigabyte

  1. PCIe Card Slot x 2

Устанавливать RAID контроллер будем в правый слот по одной простой причине: туда кабели тянуть удобно.

gigabyte

Вот наш контроллер.

gigabyte

MR SAS 9361-8i.

gigabyte

Батарейку можно было бы установить во второй PCIe слот на монтажный комплект BBU-BRACKET-05. Однако, этот слот у меня занят под сетевую карту, поэтому батарейка прекрасно притягивается стяжками в слот OCP 3.0.

gigabyte

На контроллер ставим CacheVault Flash Module (LSICVM02) а именно CVFM04.

lsi

Подключаем кабелем к батарейке.

gigabyte

Устанавливаем контроллер в райзер.

Протягиваем кабели GIGABYTE 25CFM-800821-A4R. Подключаем вместо кабелей SATA0 и SATA1.

gigabyte

Схема подключения SATA0:

gigabyte

Схема подключения SATA1:

gigabyte

Кабели 25CFM-800821-A4R протягиваем точно так же.

gigabyte

Подключаем к объединительной плате (бэкплейн), крепим стяжками.

gigabyte

Старые кабели отсоединяем.

gigabyte

Подключаем кабели к контроллеру.

gigabyte

Устанавливаем райзер с контроллером, фиксируем финтом.

gigabyte

К RAID контроллеру у нас теперь подключены слоты с HDD0 по HDD7. Установим диски.

gigabyte

Четыре диска SSD 6.4 ТБ.

Samsung SSD 6.4 ТБ — MZILT6T4HALA-00007

gigabyte

Четыре диска HDD 900 ГБ.

gigabyte

Собираем, включаем, радуемся.

Цены

mcmurphy94 писал(а):Ок, спасибо!
А как правильно сделать — после создания массива запустить инициализацию (если не была выбрана опция инициализировать сразу после создания)? Это актуально и для SAS и для SSD?

Не уверен, что понял, как второй вопрос из вышеотквоченного сочетается/связан со первым.
Мои семантические фильтры сбоят?

Актуальна ли инициализация массива как для HDD, так и для SSD???
Или актуальна ли инициализация массива как для SAS, так и для SATA носителей?

И по запуску тоже как-то коряво спрошено.

Даже если Вы не включите фоновую инициализацию и откажетесь инициализировать массив после его создания (если БИОС контроллера допускает такое вольнодумство ), то у Вас остаётся возможность «подстраховаться» впоследствии, задействовать механизмы PR или СС (см.ниже).

mcmurphy94 писал(а):Утилита от LSI MSM не пишет, был ли проинициализирован массив. Если запустить инициализацию, предупреждает, что данные будут потеряны. Это действительно так, если есть файлы, то их затрет?

Это вопросы к создателям утилиты MSM (хотя я бы их — за одну лишь тормозную явовскую морду и вечный косяк с multicast/unicast-коннектами к сетевым агентам — просто распнул бы… не смертельным, но очччень обидным образом).

Надеюсь, что про потерю данных они так «шутят»-перестраховываются. Т.к. инициализация массива может проводиться контроллером в т.ч. и в фоновом режиме прямо в процессе работы контроллера с данными на носителях.
Если это ТА ЖЕ инициализация, то нафига так пугать народ?
А если это «какая-то другая» инициализация, то… какая?

Вообще же из более-менее детальной проработки документации у меня по некоторым признакам сложилось впечатление, что пресловутая «инициализация массива» — неважно, фоновая она, или «фронт-эндная» — использует тот же механизм/алгоритм, что и так называемое «патрульное чтение» (Patrol Reading), проверяя абсолютно все блоки носителей на читабельность (и при нужде — на писабельность), с соответствующими выводами (аналог ремапа битых физ.секторов, проводимого внутри hdd или ssd их собственными фирмварями).
По итогам инициализации в метаданные массива записывается помимо прочего ещё и инфа о состоянии носителей (указание на имеющиеся «ремапы», пометки в Bad Strip Table, etc.).
И да — и инициализация, и Patrol Reading абсолютно недеструктивны для данных на массиве (конечно, при штатном развитии событий, что является нормой для исправного контроллера).

mcmurphy94 писал(а):К сравнению, интеловский рейд на С600 и утилита Intel Rapid позволяет запускать инициализацию на массиве с файлами и ничего не затирается. У них разные подходы?

Если у этого «чипсетного недорейда» ничего не затирается, значит его создатели пошли по стандартному пути (см.вышеописанный алгоритм).
Повторюсь — LSI (как и остальные вендоры) реализовал точно такой же механизм инициализации, по сути стандарт.
Почему MSM пугает уничтожением данных — «вопрос не по окладу»(с).

mcmurphy94 писал(а):И еще — когда надо провести проверку консистентности — уже после заполенения массива файлами, или нет?

Если Вы имеете в виду СС — Check Consistency — то она, в отличие от Patrol Reading, работает только на блоках с данными (PP проверяет все блоки без исключения).
Соответственно, запускать СС на пустом массиве бесполезно.

Вот вкратце как-то так…

Company
Avago
Model
MegaRAID SAS 9361-8i
Operating system
  • Unknown OS
File type
  • Manual
Version
April 2014, Rev B


32-bit

View the archive contents

Did you find what you looked for?

Useful

0 %



0



Commentary

Your name

Понравилась статья? Поделить с друзьями:
0 0 голоса
Рейтинг статьи
Подписаться
Уведомить о
guest

0 комментариев
Старые
Новые Популярные
Межтекстовые Отзывы
Посмотреть все комментарии
  • Ошейник чистотел для кошек инструкция
  • Анурин капли ушные инструкция
  • Спазмалгон инструкция по применению аналог
  • Дексалгин инструкция уколы побочные действия
  • Можжевельник трава инструкция по применению